Le design des lentilles toriques perméables au gaz : Aussi simple que 1-2-3
DOI:
https://doi.org/10.65636/cjo.v69i3.7242Keywords:
lentilles toriques perméables au gaz, lentilles, Mandell-Moore, bi-toriquesAbstract
It is well known that patients with moderate to high astigmatism are best corrected with the use of gas permeable contact lenses (RGP). They provide a sharper visual acuity, and a better ocular health compared with conventional soft contact lenses that have a limited parameters and oxygen permeability. Finally, it is recognized that the incidence of adverse events is lower on a RGP contact lens wearer’s population.
However, even when all of these benefits are considered, toric RGP lenses represent less than 1% of the contact lens market. This underutilisation could probable be explained by the fact that practitioners consider them too complicated to design and to manufacture. Initial discomfort can also play a role for the first time wearers and could make optometrists reluctant to try this option.
This article aims to demystify the theorical approach of toric RGP lenses. Using a simple and logic, step by step approach, this article will help the clinician to determine which type of toric lenses represents the optimal solution and how to design them. Through several examples, easy calculations will be made in order to achieve the better outcome in fitting, and in providing the sharpest and clearest visual acuity for the patient.
Based on this article, at the end, it will be easy for any optometrist to make optimal clinical decisions for the benefits of their patients with moderate to high astigmatism.
References
1. Efron N. The case against rigid contact lenses. Eye and Contact Lens; 29(1S): S122-S126. 2003. DOI: https://doi.org/10.1097/00140068-200301001-00033
2. Jones D, Woods CA. Contact Lens Prescribing in Canada 2006. Can J Optom; 68(6):231-237. 2006. DOI: https://doi.org/10.15353/cjo.v68i6.4629
3. Fonn D, Gauthier CA, Pritchard N. Patient preferences and comparative ocular responses to rigid and soft contact lenses. Optom Vis Sci; 72:857-863. 1995. DOI: https://doi.org/10.1002/j.1538-9235.1995.tb03992.x
4. Polse KA, Graham AD, Fusaro RE, Gan CM, Rivera RK, Chan JS, McNamara NA, Sanders TS. Predicting RGP daily wear success. CLAO J Jul; 25(3):152-8, 1999.
5. McMahon TT. The Case for Rigid Lenses. Eye and Contact Lens; 29(1S):S119-S121. 2003. DOI: https://doi.org/10.1097/00140068-200301001-00032
6. Astin, CLK. Contact Lens Fitting in High Degree Myopia. Contact Lens Ant Eye; 22: S14-S19. 1999. DOI: https://doi.org/10.1016/S1367-0484(99)80038-1
7. Morgan PB, Efron SE, Efron N, Hill EA. Inefficacy of aspheric soft contact lenses for the correction of low levels of astigmatism. Optom Vis Sci Sep; 82(9).823-8. 2005. DOI: https://doi.org/10.1097/01.opx.0000177792.62460.58
8. Silbert. J.A. Bitorics made simple. Review of Contact Lenses Oct:16-21. 2003.
9. Silbert, J.A. Rigid Lens Correction of Astigmatism. in Bennett-Weissman Clinical Contact Lens Practice. Lippincott Williams & Wilkins. Philadelphia. 1998. Chapter 40.
10. Johnson, J.D. Bennett, E.S. Material Selection in Bennett-Weissman Clinical Contact Lens Practice. Lippincott Williams & Wilkins. Philadelphia. 1998.Chapter 21.
11. Korb DR, Korb JE. A New Concept in Contact Lens Design. Part I and II. Journal Am Optom Ass; 41(12): 1023-1034. 1970.
12.Sarver MD, Kame RT, Williams CE. A bitoric gas permeable hard contact lens with spherical power effect. J Am Optom Assoc Mar; 56(3):184-9. 1985.
13. Mandell RM, Moore CE A bitoric guide that is really simple. Contact Lens Spectrum; 3: 83-85. 1988.
14. Pitts K, Pack L, Edmonston W, Pack CE. Putting a Bitoric RGP Lens Fitting Guide to The Test. Contact Lens Spectrum Oct; 16(10): 34-40. 2001.
15. Bennett, E.S. Basic Fitting in Bennett-Weissman Clinical Contact Lens Practice. Lippincott Williams & Wilkins. Philadelphia. 1998. Chapter 23.
16. Harvitt DM, Bonanno JA. Re-evaluation of the oxygen diffusion model for predicting minimum contact lens Dk/t values needed to avoid corneal anoxia. Optom Vis Sci Oct; 76(10): 712-9. 1999. DOI: https://doi.org/10.1002/j.1538-9235.1999.tb05531.x
17. Site internet du Gas Permeable Lens Institute, site destine a l’education offert par le Contact Lens Manufacturers Association (CLMA): www.rgpli.org/ mandell.htm.
Published
How to Cite
Issue
Section
License

This work is licensed under a Creative Commons Attribution-NonCommercial-NoDerivatives 4.0 International License.