Vision Screening with a Microcomputer: Validation of Two Computerized Acuity Tests

Authors

  • B.D. Johnson
  • M.J. Samak

DOI:

https://doi.org/10.65636/cjo.v51i3.7020

Keywords:

vision screening, microcomputer, accuity test

Abstract

The purpose of this study was to evaluate two computerized acuity tests which represent part of a battery of computerized assessment procedures that may be used for vision screening. Habitual monocular acuities of 20 subjects were evaluated using eye charts generated by a microcomputer. In one procedure (AC), subjects were asked to identify alphabetical characters ranging in size from 6/24 (20/80) to 6/6 (20/20). In the other procedure (TE), subjects were asked to identify illiterate E characters, which were shown over the same acuity range. The results of the computerized procedures were compared to acuity measurements obtained using non-serifed Snellen charts. Both computerized tests were validated. A regression analysis revealed that the computerized esti­mates of visual acuity differed from the clinical measurement by one optotype, given five, at the threshold level. Since both the alphabetical and illiterate E characters produced similar and valid results, it is suggested that the present tests may be of value for screening visual acuity in reading and non­reading groups.

References

1. Timberlake, George, Mainster, Martin A, and Schepens, Charles L. Automated Clinical Visual Acuity Testing. American Journal of Ophthalmology. Vol 90: 369-373. 1980. DOI: https://doi.org/10.1016/S0002-9394(14)74918-9

2. Friendly, David S and Wiess, Ira P. An Automated Visual Acuity Testing Computer Program Using the Apple II System. American Journal of Ophthalmology. Vol 99: 188-192. 1985. DOI: https://doi.org/10.1016/0002-9394(85)90231-4

3. Allen, Merrill J. Accommodative Rock via Computer. Journal of the American Optometric Association. Vol 59(8): 610-613. 1988.

4. Yeager, Dwayne and Boltz, Roger L. Compu­terized Fixation Disparity Measurement. American Journal of Optometry and Physiolog­ical Optics. Vol 63(8): 654-661. 1986. DOI: https://doi.org/10.1097/00006324-198608000-00009

5. Edworthy, GA. An Evaluation of the Micro­computer as a Vision Screening Medium. Canadian Journal of Optometry. Vol 47(4): 157-161. 1985. DOI: https://doi.org/10.15353/cjo.v47i4.4458

6. Payor, Rick. Performance of Video-Displayed Letter Charts. Clinical and Experimental Optometry. Vol 69(2): 73-76. 1986. DOI: https://doi.org/10.1111/j.1444-0938.1986.tb04572.x

7 . Personal communication, meeting with representatives from Peel Region Public Health Dept., City of Toronto Public Health, and Etobicoke Public Health Dept, August, 1988.

Published

2026-06-22

How to Cite

Johnson, B., & Samak, M. (2026). Vision Screening with a Microcomputer: Validation of Two Computerized Acuity Tests . Canadian Journal of Optometry, 51(3), 117–119. https://doi.org/10.65636/cjo.v51i3.7020

Issue

Section

Original Research